An anionic exchange stir rod sorptive extraction based on monolithic material for the extraction of non-steroidal anti-inflammatory drugs in environmental aqueous samples ( SCI-EXPANDED收录 EI收录)
文献类型:期刊文献
英文题名:An anionic exchange stir rod sorptive extraction based on monolithic material for the extraction of non-steroidal anti-inflammatory drugs in environmental aqueous samples
作者:Luo, Yan-Bo[1];Zheng, Hao-Bo[1];Wan, Jian-Xing[1,2];Gao, Qiang[1,3];Yu, Qiong-Wei[1];Feng, Yu-Qi[1]
第一作者:Luo, Yan-Bo
通讯作者:Feng, YQ[1]
机构:[1]Wuhan Univ, Key Lab Analyt Chem Biol & Med, Minist Educ, Dept Chem, Wuhan 430072, Peoples R China;[2]Xinxiang Univ, Coll Chem & Chem Engn, Xinxiang 453000, Peoples R China;[3]China Univ Geosci, Fac Mat Sci & Chem Engn, Wuhan 430074, Peoples R China
第一机构:Wuhan Univ, Key Lab Analyt Chem Biol & Med, Minist Educ, Dept Chem, Wuhan 430072, Peoples R China
通讯机构:[1]corresponding author), Wuhan Univ, Key Lab Analyt Chem Biol & Med, Minist Educ, Dept Chem, Wuhan 430072, Peoples R China.
年份:2011
卷号:86
期号:1
起止页码:103-108
外文期刊名:TALANTA
收录:;EI(收录号:20114614510981);Scopus(收录号:2-s2.0-80755188865);WOS:【SCI-EXPANDED(收录号:WOS:000298126300012)】;
基金:This work was partly supported by the National Nature Science Fund (91017013, 31070327, 21005057) and the Science Fund for Creative Research Groups (No. 20921062), NSFC. We would also like to thank Mr. Gedeng Ruan (Rice University) for his advice and reading manuscript).
语种:英文
外文关键词:Stir rod sorptive extraction; Non-steroidal anti-inflammatory drugs; Poly(4-vinylpyridine-co-ethylene glycol dimethacrylate); Monolithic material; Environmental aqueous samples
摘要:In this study, a stir rod sorptive extraction (SRSE) adsorbent material was prepared by coating poly(4-vinylpyridine-co-ethylene glycol dimethacrylate) [poly(VP-co-EDMA)] monolithic polymer on stir rod, and then applied to the extraction of three non-steroidal anti-inflammatory drugs (NSAIDs) in environmental aqueous samples. The preparation conditions of monolithic material such as the amount of porogen and the ratio of functional monomer to cross-linker were investigated. To achieve the best extraction efficiency, several parameters, including pH value of sample solution, salt concentration in sample matrix, desorption solvent, extraction time, and desorption time, were optimized. By combining SRSE and high performance liquid chromatography with ultraviolet detector, a SRSE-HPLC/UV method for the determination of NSAIDs in environmental aqueous samples was proposed successfully. The limits of detection (LODs) of the developed method for three NSAIDs ranged between 0.09 and 0.25 ng/mL. Good method reproducibility presented as intra- and inter-day precisions were also obtained with the relative standard deviations (RSDs) less than 8.7% and 9.8%, respectively. (C) 2011 Elsevier B.V. All rights reserved.